Home » Product List » Gas Generator » Natural Gas Generator Sets, 100-625kW, Cummins Engine
Product Details
Natural Gas Generator Sets, 100-625kW, Cummins Engine
| Model NO.: | FNGC100-625 |
|---|
Product Description
The natural gas generator is equipped with Cummins engine.
| Manufacturer | FORUNE Power System | |||
| GROUP | Model | FNGC100 | ||
| | Power | Prime Power(kw/kva) | 100/125 | |
| | | |||
| | 0.8 p.f | Standby Power(kw/kva) | 110/137.5 | |
| | Dimension(L*W*H) | mm | 2500*850*1500 | |
| | Weight | Kg | 1850 | |
| | Engine Manufacturer | CUMMINS | ||
| GAS ENGINE | Model | 6CTAA8.3G2T | ||
| | Aspiration & Cooling | Turbocharged | ||
| | Cylinders Capacity | Lt | 6 | |
| | Cylinders & Build | L | ||
| | Engine Speed | RPM | 1500 | |
| | Bore & Stroke | Mm*mm | 114X134 | |
| | Compression Ratio | 10.5:1 | ||
| | Governor | E | ||
| | Air Flow | m 3 //h | 479 | |
| | Natural Gas Flow | m 3 //h | 38 | |
| | Exhaust Gas Flow | m 3 //h | 1549 | |
| | GAS consumption | m 3 /kwh | < 0.25 | |
| | Oil consumption | g/kwh | <1.6 | |
| | Heat Consumption | MJ/kWh | 11 | |
| | Intake Gas Pressure Required | kPa | 80-200 | |
| | Fan-air Flow | m 3 //h | 5.8 | |
| | Coolant Capacity | Litre | 31 | |
| | Coolant Flow (kg/s) | kg/s | 3.7 | |
| | Lube oil Capacity | Litre | 23.6 | |
| | Manufacturer | LEROY SOMER | ||
| Alternator | Model | LSA44.2S7 | ||
| | Excitation | Brushless, AVR | ||
| | Output Voltage | V | 400/230 | |
| | Voltage Adjusting Range | >= +/- 6% | ||
| | Steady Voltage Adjusting Range | <= +/- 1% | ||
| | Insulation | H | ||
| | Protection | IP23 | ||
| Manufacturer | Fortune Power System | |||
| GROUP | Model | FNGC140 | ||
| | Power | Prime Power(kw/kva) | 140/175 | |
| | | |||
| | 0.8 p.f | Standby Power(kw/kva) | 154/192.5 | |
| | Dimension(L*W*H) | mm | 2950*1050*1541 | |
| | Weight | Kg | 3360 | |
| | Engine Manufacturer | CUMMINS | ||
| GAS ENGINE | Model | NTA855G1A | ||
| | Aspiration & Cooling | Turbocharged | ||
| | Cylinders Capacity | Lt | 6 | |
| | Cylinders & Build | L | ||
| | Engine Speed | RPM | 1500 | |
| | Bore & Stroke | Mm*mm | 140X152 | |
| | Compression Ratio | 10.5:1 | ||
| | Governor | E | ||
| | Air Flow | m 3 //h | 615 | |
| | Natural Gas Flow | m 3 //h | 49 | |
| | Exhaust Gas Flow | m 3 //h | 1984 | |
| | GAS consumption | m 3 /kwh | < 0.30 | |
| | Oil consumption | g/kwh | <1.6 | |
| | Heat Consumption | MJ/kWh | 11 | |
| | Intake Gas Pressure Required | kPa | 80-200 | |
| | Fan-air Flow | m 3 //h | 7.5 | |
| | Coolant Capacity | Litre | 63 | |
| | Coolant Flow (kg/s) | kg/s | 4.7 | |
| | Lube oil Capacity | Litre | 36.7 | |
| | Manufacturer | LEROY SOMER | ||
| Alternator | Model | LSA46.2M3 | ||
| | Excitation | Brushless, AVR | ||
| | Output Voltage | V | 400/230 | |
| | Voltage Adjusting Range | >= +/- 6% | ||
| | Steady Voltage Adjusting Range | <= +/- 1% | ||
| | Insulation | H | ||
| | Protection | IP23 | ||
| Manufacturer | Fortune Power System | |||
| GROUP | Model | FNGC168 | ||
| | Power | Prime Power(kw/kva) | 168/210 | |
| | | |||
| | 0.8 p.f | Standby Power(kw/kva) | 185/231 | |
| | Dimension(L*W*H) | mm | 3155*1050*1541 | |
| | Weight | Kg | 3550 | |
| | Engine Manufacturer | CUMMINS | ||
| GAS ENGINE | Model | NTA855G2A | ||
| | Aspiration & Cooling | Turbocharged Aftercooled | ||
| | Cylinders Capacity | Lt | 6 | |
| | Cylinders & Build | L | ||
| | Engine Speed | RPM | 1500 | |
| | Bore & Stroke | Mm*mm | 140X152 | |
| | Compression Ratio | 10.5:1 | ||
| | Governor | E | ||
| | Air Flow | m 3 //h | 738 | |
| | Natural Gas Flow | m 3 //h | 58 | |
| | Exhaust Gas Flow | m 3 //h | 2380 | |
| | GAS consumption | m 3 /kwh | < 0.30 | |
| | Oil consumption | g/kwh | <1.6 | |
| | Heat Consumption | MJ/kWh | 12 | |
| | Intake Gas Pressure Required | kPa | 80-200 | |
| | Fan-air Flow | m 3 //h | 9 | |
| | Coolant Capacity | Litre | 63 | |
| | Coolant Flow (kg/s) | kg/s | 5.7 | |
| | Lube oil Capacity | Litre | 36.7 | |
| | Manufacturer | LEROY SOMER | ||
| Alternator | Model | LSA46.2L6 | ||
| | Excitation | Brushless, AVR | ||
| | Output Voltage | V | 400/230 | |
| | Voltage Adjusting Range | >= +/- 6% | ||
| | Steady Voltage Adjusting Range | <= +/- 1% | ||
| | Insulation | H | ||
| | Protection | IP23 | ||
| GROUP | Manufacturer | Fortune Power System | ||
| Model | FNGC200 | |||
| Power | Prime Power(kw/kva) | 200/250 | ||
| | ||||
| 0.8 p.f | Standby Power(kw/kva) | 220/275 | ||
| Dimension(L*W*H) | mm | 3443*1300*1916 | ||
| Weight | Kg | 4630 | ||
| GAS ENGINE | Engine Manufacturer | CUMMINS | ||
| Model | KTA19G2 | |||
| Aspiration & Cooling | Turbocharged | |||
| Cylinders Capacity | Lt | 6 | ||
| Cylinders & Build | L | |||
| Engine Speed | RPM | 1500 | ||
| Bore & Stroke | Mm*mm | 1159X159 | ||
| Compression Ratio | 10.5:1 | |||
| Governor | E | |||
| Air Flow | m 3 //h | 878 | ||
| Natural Gas Flow | m 3 //h | 69 | ||
| Exhaust Gas Flow | m 3 //h | 2834 | ||
| GAS consumption | m 3 /kwh | < 0.30 | ||
| Oil consumption | g/kwh | <1.6 | ||
| Heat Consumption | MJ/kWh | 11 | ||
| Intake Gas Pressure Required | kPa | 80-200 | ||
| Fan-air Flow | m 3 //h | 10.7 | ||
| Coolant Capacity | Litre | 91 | ||
| Coolant Flow (kg/s) | kg/s | 6.8 | ||
| Lube oil Capacity | Litre | 50 | ||
| Alternator | Manufacturer | LEROY SOMER | ||
| Model | LSA46.2L6 | |||
| Excitation | Brushless, AVR | |||
| Output Voltage | V | 400/230 | ||
| Voltage Adjusting Range | >= +/- 6% | |||
| Steady Voltage Adjusting Range | <= +/- 1% | |||
| Insulation | H | |||
| Protection | IP23 | |||
| GROUP | Manufacturer | Fortune Power System | ||
| Model | FNGC625 | |||
| Power | Prime Power(kw/kva) | 500/625 | ||
| | ||||
| 0.8 p.f | Standby Power(kw/kva) | 550/687.5 | ||
| Dimension(L*W*H) | mm | 5350*1980*2310 | ||
| Weight | Kg | 9800 | ||
| GAS ENGINE | Engine Manufacturer | CUMMINS | ||
| Model | KTA50G3T | |||
| Aspiration & Cooling | Turbocharged | |||
| Cylinders Capacity | Lt | 12 | ||
| Cylinders & Build | V60 | |||
| Engine Speed | RPM | 1500 | ||
| Bore & Stroke | Mm*mm | 159X159 | ||
| Compression Ratio | 10.5:1 | |||
| Governor | E | |||
| Air Flow | m 3 //h | 2195 | ||
| Natural Gas Flow | m 3 //h | 174 | ||
| Exhaust Gas Flow | m 3 //h | 7085 | ||
| GAS consumption | m 3 /kwh | < 0.30 | ||
| Oil consumption | g/kwh | <1.6 | ||
| Heat Consumption | MJ/kWh | 11 | ||
| Intake Gas Pressure Required | kPa | 80-200 | ||
| Fan-air Flow | m 3 //h | 26.8 | ||
| Coolant Capacity | Litre | 180 | ||
| Coolant Flow (kg/s) | kg/s | 16.9 | ||
| Lube oil Capacity | Litre | 161 | ||
| Alternator | Manufacturer | LEROY SOMER | ||
| Model | LSA49.1S4A | |||
| Excitation | Brushless, AVR | |||
| Output Voltage | V | 400/230 | ||
| Voltage Adjusting Range | >= +/- 6% | |||
| Steady Voltage Adjusting Range | <= +/- 1% | |||
| Insulation | H | |||
| Protection | IP23 | |||
Inquiry Basket (